On-Grid Inverter with Energy Storage

1. Pure sine wave output

2. Self-consumption and deed in to the grid

3. Programmable supply priority for PV,Battery or Grid

4. User-adjustable battery charging current suits different types of batteries

5. Programmable multiple operation modes: Grid-tie,Off-grid and grid-tie with backup

6. Built-in timer for various mode of on/off operation

7. Multiple communication for USB,RS232,Modbus and SNMP

8. Monitoring software for rel-time status display and control

9. Parallel operation up to 6 units for 10KW



Quick Inquiry

Technical Specifications:

Model HYG5032 HYG5532 HYG1033
PHASE 1-phase in/1 phase out 1-phase in/1 phase out 3-phase in/3-phase out
Max. PV INPUT POWER 5000W 6500W 14850W
Rated Output Power 5000W 5500W 10000W
Maximum Charging Power 4800 W 2880 W 9600 W
GRID TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage/Max. DC Voltage 720 VDC/900 VDC 360 VDC/500 VDC 720 VDC/900 VDC
Start-up Voltage/Initial Feeding Voltage 225 VDC/250 VDC 116 VDC/150 VDC 320 VDC/350 VDC
MPP Voltage Range 250 VDC~850 VDC 120 VDC~450 VDC 400 VDC~800 VDC
Number of MPP Trackers/ 2/2x10A 2/2x13A 2/2x18.6A
Maximum Input Current
GRID OUTPUT (AC)
Nominal Output Voltage 208/220/230/240 VAC 208/220/230/240 VAC 230 VAC (P-N)/
400 VAC (P-P)
Output Voltage Range 184 -265 VAC* 184 -265 VAC* 184 - 265 VAC* per phase
Nominal Output Current 21A 23.9A 14.5A per phase
Power Factor > 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) 96%
European Efficiency@Vnominal 95%
OFF GRID OPERATION
AC INPUT
AC start-up Voltage/ 120-140 VAC/180 VAC 120-140 VAC/180 VAC 120-140 VAC per phase/
Auto Restart Voltage 180 VAC per phase
Acceptable Input Voltage Range 170-280 VAC 170-280 VAC 170-280 VAC per phase
Max. AC Input Current 21A 40A 40A
PV INPUT (DC)
Max. DC Voltage 900 VDC 500 VDC 900 VDC
MPP Voltage Range 250 VDC~850 VDC 120 VDC~450 VDC 400 VDC~800 VDC
Number of MPP Trackers/Max. Input Current 2/2x10A 2/2x13A 2/2x18.6A
BATTERY Mode Output (AC)
Nominal Output Voltage 202/208/220/230/240 VAC 202/208/220/230/240 VAC 230 VAC (P-N)/400 VAC (P-P)
Output Waveform Pure Sine Wave
Efficiency (DC to AC) 93% 93% 91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage/Max. DC Voltage 720 VDC/900 VDC 360 VDC/500 VDC 720 VDC/ 900 VDC
Start-up Voltage/Initial Feeding Voltage 225 VDC/ 250 VDC 116 VDC/150 VDC 320 VDC/ 350 VDC
MPP Voltage Range 250 VDC~ 850 VDC 120 VDC~450 VDC 400 VDC~800 VDC
Number of MPP Trackers/Max. Input Current 2/2x10A 2/2x13A 2/2x18.6A
GRID OUTOUT (AC)
Nominal Output Voltage 202/208/220/230/240 VAC 202/208/220/230/240 VAC 230 VAC (P-N)/
400 VAC (P-P)
Output Voltage Range 184-264.5 VAC* 184-264.5 VAC* 184-264.5 VAC* per phase
Nominal Output Current 21A 23.9A 14.5A per phase
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 120-140 VAC/180 VAC 120-140 VAC/180 VAC 120-140 VAC per phase/
180 VAC per phase
Acceptable Input Voltage Range 170-280 VAC 170-280 VAC 170-280 VAC per phase
Max. AC Input Current 30A 30A 40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 202/208/220/230/240 VAC 202/208/220/230/240 VAC 230 VAC (P-N)/
400 VAC(P-P)
Efficiency (DC to AC) 93% 93% 91%
BATTERY& CHARGER
Battery DC Voltage 48V
Max. Charging Current Default 60A Default 60A, 10A-200A (Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm) 204.2 x 460x 600 110*450*445 167.5 x 500 x 622
Net weight (kgs) 29 16 45
INTERFACE
Communication Port RS-232/USB and CAN Interface
ENVIRONMENT
Humidity 0 ~90%RH
Operating Temperature -10 to 55 ° C 0 to 40°C -10 to 55 °C
Altitude 0-1000 m**


Quick Inquiry